ASTM D1143 PDF

ASTM D Test Method for Piles Under Static Axial Compressive Load This standard has been. prepared to cover routine methods of testing to determine if a . Grout Systems performs compression load testing based on ASTM D, the standard test method for deep foundations under static axial compressive load. ASTM D Standard Test Method for Piles under Static Axial Compressive Load.

Author: Dakus Bacage
Country: New Zealand
Language: English (Spanish)
Genre: Literature
Published (Last): 5 October 2010
Pages: 406
PDF File Size: 9.56 Mb
ePub File Size: 8.93 Mb
ISBN: 559-3-98797-761-4
Downloads: 19947
Price: Free* [*Free Regsitration Required]
Uploader: Meztigore

Loading in Excess of Maintained Test Optional. Constant Movement Increment Test Optional.

How one applies the results obtained using this standard is beyond its awtm. See Appendix X1 for comments regarding some of the factors influencing the interpretation of test results. Test results can be evaluated to determine if the pile or pile group has an ultimate static capacity and a deflection at service load satisfactory to support a specific foundation.

Compression load tests apply to all deep foundations that function in a manner similar to driven piles or cast-in-place piles, regardless of their method of installation, and may be used for testing single piles or pile groups. These notes and footnotes excluding those in tables and figures shall not be considered as requirements of the standard.

The quality of the result produced by this test method is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used.

The text of this standard references notes and footnotes which provide explanatory material. Constant Rate of Penetration Test Optional.

Tests that achieve a failure load may help the designer improve the efficiency of the foundation by reducing the piling length, quantity, or size. Reliable results depend on many factors; Practice D provides a means of evaluating some of those factors.

  AGFEO AS 181 PLUS PDF

Compression (ASTM D1143)

Users of this test method are cautioned that compliance with Practice D does not in itself assure reliable results. Imperative sentences indicate mandatory provisions. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Link to Active This link will always route to the current Active version of the standard. Procedure A Quick Test 8.

The test measures the axial deflection of a vertical or inclined deep foundation when loaded in static axial compression. Grout Systems Incorporated Grout Systems. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

When performed as part of a multiple-pile test program, the results may also be used to assess the viability of different piling types and the variability of the test site. This standard also includes illustrations and appendices intended only for explanatory or advisory use. Grout Systems performs compression load testing based on ASTM D, the standard ast method for deep foundations under static axial compressive load.

Historical Version s – view previous versions of standard.

Combining values from the two systems may result in non-conformance with the standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Interested in compression pile load testing, contact the experienced team at Grout Systems.

Compression Load Tests provide the most reliable relationship between the axial load applied to a deep foundation and the resulting axial movement. A foundation designer may evaluate the test results e1143 determine if, after applying an appropriate factor of safety, the pile or pile group has an ultimate static capacity and a deflection at service load satisfactory to support a specific foundation.

  CIENCIAS BIOLOGICAS YADITZHA IRAUSQUIN PDF

Test results may also provide information used to assess the distribution of side shear resistance along the pile shaft, the amount of end bearing developed at the pile toe, and the long-term load-deflection behavior. When performed as part of a multiple-pile test program, the designer may also use the results to assess the viability of different piling types and the variability of the test site.

Compression (ASTM D) | Grout Systems

Test results may also provide information used to assess the distribution of side shear resistance along the pile shaft, the amount of end bearing developed at the pile toe, and the long-term load-deflection behavior. The test results may not represent the long-term performance of a deep foundation. Constant Time Interval Test Optional. In this system, the pound [lbf] represents a unit of force [weight], while the unit for mass is slugs.

These methods apply to all deep foundations, referred to herein as pilesthat sstm in a manner similar to driven piles or cast-in-place piles, regardless of their method of installation, and may be used for testing single piles or pile groups.

Cyclic Loading Test Optional. The engineer in responsible charge of the foundation design, referred to herein as the Engineer, shall approve any deviations, deletions, or additions to the requirements of this standard.